Installation Refrigerated Container
Installation Refrigerated Container
What is the use of a Reefer?
A reefer 40 feet consumes an average of 7 km/hour worked, while in regime, when it reaches the desired temperature (set point) to automatically.
What is required to implement a Reefer?
There must be a supply of three-phase power equivalent to 15 kw or higher to support the initial set up of the engines.
Can be connected with other machines, a time that the facilities are adequate and safe. Improper connections can cause poor contact and impair the functioning of the Containers, causing the burning of the electronic boards of the control of the temperature as well as other components.
The container has 1 cable, black is to be connected to 460 or 480 volt. This cable is 4 x 6 mm, three-phase and one earth that also needs to be connected.
What circuit should I use it?
In 460 or 480 volts should be using a circuit breaker three-pole 32 to 40 amps.
What are the main care should I take after the
installation of a container?
Wash the condenser (a kind of radiator that is located with the engine) at least once a week and cleaning of the engines of the evaporators.
The cooling unit should be more than 5 feet away from a wall of cement or other materials.
In the space provided to be put in the container must have air inlets or good ventilation.
What voltage works a Reefer?
The Reefers are working with three-phase power and the voltage of 460 to 480 and 32 Amps.
Photo illustrative of 1 x 40’ HC REFRIGERATED
Click to see the full picture of information.